28. 03. 2024. 13:00

Stealth Shouldered Abutments

Stealth Shouldered Abutments with a 3.0mm Post

Description Dia. Height Angle Post Part Number
4.0 x 1.5mm 0° Stealth Abutment 3.0mm Post 4.0mm 1.5mm 3.0mm 260-300-300
4.0 x 3.5mm 0° Stealth Abutment 3.0mm Post 4.0mm 3.5mm 3.0mm 260-300-400
5.0 x 2.0mm 0° Stealth Abutment 3.0mm Post 5.0mm 2.0mm 3.0mm 260-300-301
5.0 x 2.0mm 10° Stealth Abutment 3.0mm Post 5.0mm 2.0mm 10° 3.0mm 260-300-302
5.0 x 3.0mm 0° Stealth Abutment 3.0mm Post 5.0mm 3.0mm 3.0mm 260-300-311
5.0 x 3.0mm 10° Stealth Abutment 3.0mm Post 5.0mm 3.0mm 10° 3.0mm 260-300-312
5.0 x 4.0mm 0° Stealth Abutment 3.0mm Post 5.0mm 4.0mm 3.0mm 260-300-321
5.0 x 4.0mm 10° Stealth Abutment 3.0mm Post 5.0mm 4.0mm 10° 3.0mm 260-300-322
5.0 x 6.0mm 0° Stealth Abutment 3.0mm Post 5.0mm 6.0mm 3.0mm 260-300-341
5.0 x 6.0mm 10° Stealth Abutment 3.0mm Post 5.0mm 6.0mm 10° 3.0mm 260-300-342
6.5 x 2.0mm 0˚ Stealth Abutment 3.0mm Post 6.5mm 2.0mm 3.0mm 260-300-601
6.5 x 2.0mm 10˚ Stealth Abutment 3.0mm Post 6.5mm 2.0mm 10° 3.0mm 260-300-602
6.5 x 4.0mm 0˚ Stealth Abutment 3.0mm Post 6.5mm 4.0mm 3.0mm 260-300-621
6.5 x 4.0mm 10˚ Stealth Abutment 3.0mm Post 6.5mm 4.0mm 10° 3.0mm 260-300-622

 

ss 3mm abutmenti

 

Stealth Shouldered Abutments with a 2.5mm Post

Description Dia. Height Angle Post Part Number
4.0 x 1.5mm 0° Stealth Abutment 2.5mm Post 4.0mm 1.5mm 2.5mm 260-250-300
4.0 x 3.5mm 0° Stealth Abutment 2.5mm Post 4.0mm 3.5mm 2.5mm 260-250-400
5.0 x 2.0mm 0° Stealth Abutment 2.5mm Post 5.0mm 2.0mm 2.5mm 260-250-301
5.0 x 2.0mm 10° Stealth Abutment 2.5mm Post 5.0mm 2.0mm 10° 2.5mm 260-250-302
5.0 x 3.0mm 0° Stealth Abutment 2.5mm Post 5.0mm 3.0mm 2.5mm 260-250-311
5.0 x 3.0mm 10° Stealth Abutment 2.5mm Post 5.0mm 3.0mm 10° 2.5mm 260-250-312
5.0 x 4.0mm 0° Stealth Abutment 2.5mm Post 5.0mm 4.0mm 2.5mm 260-250-321
5.0 x 4.0mm 10° Stealth Abutment 2.5mm Post 5.0mm 4.0mm 10° 2.5mm 260-250-322
5.0 x 6.0mm 0° Stealth Abutment 2.5mm Post 5.0mm 6.0mm 2.5mm 260-250-341
5.0 x 6.0mm 10° Stealth Abutment 2.5mm Post 5.0mm 6.0mm 10° 2.5mm 260-250-342

 

2 5mm ss 1d abutmenti

 

Stealth Shouldered Abutments with a 2.0mm Post

Description Dia. Height Angle Post Part Number
3.5 x 1.5mm 0° Stealth Abutment 2.0mm Post 3.5mm 1.5mm 2.0mm 260-200-150
3.5 x 3.0mm 0° Stealth Abutment 2.0mm Post 3.5mm 3.0mm 2.0mm 260-200-153
4.0 x 1.5mm 0° Stealth Abutment 2.0mm Post 4.0mm 1.5mm 2.0mm 260-200-200
4.0 x 3.5mm 0° Stealth Abutment 2.0mm Post 4.0mm 3.5mm 2.0mm 260-200-400
5.0 x 2.0mm 0° Stealth Abutment 2.0mm Post 5.0mm 2.0mm 2.0mm 260-200-201
5.0 x 2.0mm 10° Stealth Abutment 2.0mm Post 5.0mm 2.0mm 10° 2.0mm 260-200-202
5.0 x 4.0mm 0° Stealth Abutment 2.0mm Post 5.0mm 4.0mm 2.0mm 260-200-221
5.0 x 4.0mm 10° Stealth Abutment 2.0mm Post 5.0mm 4.0mm 10° 2.0mm 260-200-222

 

ss 2mm abutmenti

 

Stealth Abutment Short Sleeves (4)

Description Dia. Height Part Number
4.0mm Stealth Abutment Short Sleeves
Contains (4) short beige sleeves
4.0mm 6.0mm 260-250-004
5.0mm Stealth Abutment Short Sleeves
Contains (2) short yellow sleeves (2) short beige sleeves
5.0mm 6.0mm 260-250-005
6.5mm Stealth Abutment Short Sleeves
Contains (2) short green sleeves (2) short beige sleeves
6.5mm 6.0mm 260-250-006

 

stealth short sleeves abutmenti

 

Stealth Abutment Tall Sleeves (4)

Description Dia. Height Part Number
3.5mm Stealth Abutment Tall Sleeves
Contains (4) tall beige sleeves
3.5mm 10.0mm 260-250-103
4.0mm Stealth Abutment Tall Sleeves
Contains (4) tall beige sleeves
4.0mm 10.0mm 260-250-104
5.0mm Stealth Abutment Tall Sleeves
Contains (2) tall yellow sleeves (2) tall beige sleeves
5.0mm 10.0mm 260-250-105
6.5mm Stealth Abutment Tall Sleeves
Contains (2) tall green sleeves (2) tall beige sleeves
6.5mm 10.0mm 260-250-106

 

stealth tall sleeves abutmenti

 

Stealth Abutment Transfer Dies (2)

Description Dia. Part Number
3.5mm Stealth Abutment Transfer Dies
Contains 2 transfer dies and (2) tall beige sleeves
3.5mm 260-250-183
4.0mm Stealth Abutment Transfer Dies
Contains 2 transfer dies and a total of (4) sleeves: (2) short beige sleeves, (2) tall beige sleeves
4.0mm 260-250-184
5.0mm Stealth Abutment Transfer Dies
Contains 2 transfer dies and a total of (4) sleeves: (1) short yellow sleeve, (1) short beige sleeve, (1) tall yellow sleeve, and (1) tall beige sleeve
5.0mm 260-250-185
6.5mm Stealth Abutment Transfer Dies
Contains 2 transfer dies and a total of (4) sleeves: (1) short green sleeve, (1) short beige sleeve, (1) tall green sleeve, and (1) tall beige sleeve
6.5mm 260-250-186

transfer die abutmenti

 

Stealth Abutment Thin-Wall Sleeves (4)

Description Dia. Height Part Number
Stealth Sleeve for 4.0mm Stealth Abutment (4) 4.0mm 4.0mm 260-250-204
Stealth Sleeve for 5.0mm Stealth Abutment (4) 5.0mm 6.5mm 260-250-205
Stealth Sleeve for 6.5mm Stealth Abutment (4) 6.5mm 6.5mm 260-250-206

 

stealth thin wall sleeves abutmenti

 

Stealth Abutment Shoulder Depth Gauge

Description Part Number
Abutment Shoulder Depth Gauge 260-101-380

stealth depth gauge abutmenti

 

 

depth gauge measure abutmenti

 

Stealth Shouldered Abutment Considerations

  • Although the stealth shouldered abutment is designed for all-ceramic restorations, it may be used in conjunction with metal castings.
  • Use the shoulder depth gauge to determine an appropriate abutment shoulder height, relative to the gingival tissues. The first mark on the shoulder depth gauge corresponds to a 2.0mm shoulder height of a 5.0mm stealth shouldered abutment. The second mark corresponds to a 4.0mm shoulder height, etc. If the soft tissue falls in between two marks, select the shorter of the two abutment heights for an aesthetic result.
  • The diameter of an abutment is dictated by the interproximal papillae. The abutment should support the papillae without encroaching upon them.
  • The Stealth Sleeve may be used for making an impression, for creating a temporary crown, for recording an occlusal registration, and also as a waxing sleeve or a corrective coping.
  • When using the one-piece sleeve as an impression transfer, it is essential to confirm that an internal flat of the sleeve has been aligned with an external flat on the abutment.
  • Prior to the intraorally cementing of a crown on a shouldered abutment, a radiograph must be taken to ensure that the crown is fully seated.
  • A 3.5mm stealth shouldered abutment crown MUST be extra-orally cemented.